Tags
2 articles
Error 170305110, Head unit undervoltage, level-3 fault, means the battery of the AEG SolarCube Pro is discharged too deeply and the battery management system has locked it. For days the app then says Battery Force Charging Mode while 2 to 6 W goes in. Our unit drained itself off the grid, sat locked for 4 days and 5 hours after it was plugged back in, and came out on its own. What each message means, why it drains while it looks switched off, and what does and does not help.
The AEG SolarCube Pro costs € 1,799 and promises 6.0 kWh usable and a single efficiency figure. We hooked it up to our techbench for two days, walked the whole discharge curve by hand and closed the cycle: 1,165 Wh went in and 947 Wh came out. After the test, off the grid, it drained itself until the battery management system locked it out, and it only came out of that by itself 4 days and 5 hours later. Here is the full file behind the video: every figure with its origin and grid setting, the registers we mapped ourselves, the places where the product sheets contradict each other, and the fifteen things I do not know yet.