energieresearch

Home battery: safe or not? What the fire service does when one burns, and the 20 kWh that is not a limit

A home battery can catch fire. According to a German estimate, about as often as a tumble dryer, with the battery slightly higher. The NIPV report on fires with home batteries shows what the Dutch fire service does then: switching off the meter cupboard does not guarantee that the battery is voltage-free, and the response is cooling, measuring and waiting. There is no legal 20 kWh limit for a home battery in a house. With the quotes, the timeline of the 20 kWh, the steps per source and the sources.

Jooshua
31 min read
In this article15
  1. Key points
  2. What kind of report it is
  3. How often does a home battery catch fire?
  4. The meter cupboard: off is not voltage-free
  5. What the fire service does then
  6. Where it started: the three Dutch fires
  7. The 20 kWh: what the NIPV wrote, and what the rule is
  8. And your insurance?
  9. What you can do yourself: the steps, and their order
  10. And the plug-in battery?
  11. My verdict: safe or not?
  12. What is deliberately not in here
  13. Frequently asked questions
  14. Related articles
  15. Sources

Jay's Desk

TL;DR

A home battery can catch fire. According to a German estimate, about as often as a tumble dryer, with the battery slightly higher. The NIPV report on fires with home batteries shows what the Dutch fire service does then: switching off the meter cupboard does not guarantee that the battery is voltage-free, and the response is cooling, measuring and waiting. There is no legal 20 kWh limit for a home battery in a house. With the quotes, the timeline of the 20 kWh, the steps per source and the sources.

Is a home battery in your house safe? It can catch fire. So can a tumble dryer, and according to a German estimate about as often, with the battery slightly higher.

For the long answer there is a 51-page report from the Netherlands Institute for Public Safety (NIPV), the institute that supplies knowledge to the Dutch fire service. Its title: Incidentbestrijding lithium-ion thuisbatterijen (incident response for lithium-ion home batteries), published on 26 March 2026. It describes what the fire service does when a fixed home battery burns. A footnote in it also gives a limit of 20 kWh. That limit is wrong.

This article belongs to the video «Veilig of niet?» (safe or not?) on Jay's Desk, which is in Dutch. The video tells the story. Here you also get the quotes with page numbers, the timeline of the 20 kWh, the limits of the German estimate, the steps per source and what I leave out on purpose. All sources are Dutch unless stated otherwise; the quotes are our translation.

Key points

  • The meter cupboard does not guarantee that your battery is voltage-free. According to the NIPV, switching off the installation at the meter cupboard "offers no guarantee that the home battery is voltage-free". The energy in the battery stays behind (verified, NIPV 2026, p. 3-4 and p. 20).
  • The fire service cools and monitors, and stops the fire from escalating further into the surroundings. A controlled burn-out is a responsible option according to the experts in the report, if the surroundings allow it (verified, p. 4).
  • There is no legal 20 kWh limit for a home battery in a house. The guideline with that number, PGS 37-1, excludes private individuals word for word and above 20 kWh only recommends applying its measures. The ministry writes that home batteries fall outside the new decree, regardless of capacity (verified).
  • The NIPV got it right in 2025, and wrong in 2026. In January 2025, PGS 37-1 was «available» above 20 kWh. In March 2026 it was «applicable» (verified).
  • About as often as a tumble dryer. RWTH Aachen estimated the fire probability of a home battery at 0.0049% per year, against 0.0037% for a tumble dryer. Germany, 2023, counted from media reports (verified at the place of publication; the study itself was not opened).
  • In none of the three Dutch fires was a spontaneous cell defect established. Once the cause was not found, once it was the inverter of a self-built system, once a drill (derived: our own count from the report's appendices).
  • On two plug-in batteries a connection melted, without a fire. On the AEG SolarCube AS-BBL09 according to the distributor, on the Growatt AURA 5000 according to Growatt.

Info

Every claim carries a mark. Verified: read in the source, with the page where there is one. Derived: our own count or my reading. According to the distributor or according to Growatt: a claim by that party, not checked by me. Opinion: my judgement, without a count. The NIPV report was read in full on 13 November 2026. The sources are as of 13 November 2026, unless another date is given.

What kind of report it is

The NIPV report is a qualitative report, not a risk study (verified). It describes what happens when a home battery burns, and what the fire service can do then. It does not calculate how often it happens.

Basis of the reportSize
Literature study2020 up to and including 2025
Incidents8: 3 in the Netherlands, 5 abroad
Expert sessions2
Experts7, from 7 safety regions
Probability, frequency or percentagenone

(verified, NIPV 2026)

Two things follow from that. The report does not say how often a home battery catches fire. And none of the eight incidents is described as a plug-in battery (derived: our own count). So this report says nothing about the plug-in battery. Further down the plug-in battery gets its own section, with two other sources.

The five incidents abroad were only read in outline. I do not use them here.

How often does a home battery catch fire?

One estimate comes from Germany. RWTH Aachen, a university in Germany, estimated the fire probability of a home battery at 0.0049% per year. About 1 in 20,000 batteries per year. From the same study:

WhatEstimated fire probability per year
Home battery0.0049%
Tumble dryer0.0037%
Solar panels0.0014%
Fridge0.0012%
Electric car (per car)0.024%

(verified at the place of publication: pv magazine Deutschland and ESS News, both 9 December 2024)

0.0049% per year

estimated fire probability of a home battery, about 1 in 20,000 batteries per year. A tumble dryer: 0.0037%

Source: RWTH Aachen, via pv magazine Deutschland and ESS News, 9 December 2024

In this estimate, home batteries and tumble dryers catch fire about as often, with the battery slightly higher. They are not equal. According to the study, an ordinary house fire is about 50 times more likely than a fire caused by a home battery.

What sits behind the number:

  • Germany, 2023. It is not a Dutch number.
  • Counted from media reports. There are no official fire statistics for home batteries. How the study handled fires that did not make the news is not known.
  • Only fires the battery itself caused. Fires caused by the BMS or by human action do not count. A drill through the housing, as in Zoetermeer, or a self-built system, as in Kollumerpomp, would therefore not count in this tally.
  • First presented to the industry. The study was first presented at a meeting of the German energy storage industry association (BVES). It came out in October 2024 and later in the Journal of Energy Storage (2025).
  • The study itself was not opened. The publisher refused the download. So the numbers were not checked against the study itself.

The reports also give a number of fires and a number of batteries. I do not use them. Divide one by the other and you do not get 0.0049%, and how the study got from its count to that percentage is not in the reports. I cannot explain that contradiction, so the two numbers are not here.

The meter cupboard: off is not voltage-free

Say a fixed home battery catches fire at your place. The fire service arrives and switches off the main switch in your meter cupboard. Is your battery voltage-free then?

Not guaranteed. The report, word for word:

"Switching off the electrical installation at the meter cupboard by the fire service offers no guarantee that the home battery is voltage-free, so the danger of electrocution can remain."

(verified, NIPV 2026, p. 3-4 and p. 26)

The meter cupboard switches off the installation. What is stored in the battery stays there. The report calls this stranded energy: "remaining stored energy that can still deliver voltage". Contact with the battery or the housing can then lead to a danger of electrocution (verified, p. 20).

Without measuring, nobody knows if there is still voltage on it. The report:

"Without carrying out voltage measurements, however, it cannot be guaranteed that all parts of the battery are actually voltage-free."

(verified, p. 20)

The fire service still switches off the main switch. That remains the advice. It is only not a guarantee. Off at the meter cupboard does not mean your battery is off.

What the fire service does then

"In practice, the response of the Dutch fire service therefore focuses primarily on cooling, monitoring and preventing further escalation into the surroundings."

(verified, p. 3-4)

Letting it burn out

Can it be responsible to let a burning home battery burn out? According to the experts in the report, yes:

"In such situations, a controlled burn-out or reacting out, possibly combined with cooling from a distance, is seen by the experts as a responsible response option when the surroundings allow it."

(verified, p. 4)

When do the surroundings allow it? The report gives three conditions:

  1. The burn-out adds no extra danger to people and animals.
  2. The fire does not spread beyond the burning object.
  3. Nobody has to be evacuated extra because of the burn-out.

Losser: not over after the fire was out

Losser, 13 September 2023. In the garage hung a 56 kWh home battery with LFP cells, next to the garage door. "The cause of the incident has not been found." After the fire was put out, the battery went into a waste container with water on the driveway. The report:

"This was not leak-tight. Pressure built up, causing the container (filled with water) to explode."

(verified, NIPV 2026, appendices)

The flames were gone. It was not over yet.

When the battery counts as stable again

In the report, a battery only counts as stable again when two measurements agree (verified, p. 23):

  • the thermal imaging camera measures below 50 °C for 15 minutes;
  • the explosion hazard meter no longer measures flammable gases.

The report itself calls the 50 °C a "practical guide value". It is a working agreement, not a measured limit.

15 minutes below 50 °C

when a battery counts as stable again in the NIPV report, together with an explosion hazard meter that no longer measures flammable gases. The 50 °C is a practical guide value

Source: NIPV, Incidentbestrijding lithium-ion thuisbatterijen, 26 March 2026, p. 23

The smoke

On the smoke, the report writes that the experts "have the impression that a fire with a home battery does not differ significantly from a house fire without a home battery" (verified, p. 20). It is an expert judgement, not a measurement.

What remains is cooling and measuring. And waiting. Whether a burn-out is possible depends on the surroundings of the battery, with the three conditions above.

Where it started: the three Dutch fires

Place and dateBatteryLocationWhat happenedCause according to the report
Losser, 13 September 202356 kWh, LFPgarage, next to the garage doorfire; after it was put out, the container with water explodednot found
Kollumerpomp, 17 September 2025self-built off-grid battery, LFPliving roomthe occupant was "tinkering" with it; an inverter had a fault and the transformer got hot"not caused by a defect of the battery cells"
Zoetermeer, 22 October 2025stackable, 3 × 8 kWh, LFPgaragea hole drilled from the living room; "A jet of flame came out of the drill hole."the drill; the system was "correctly connected"

(verified, NIPV 2026, appendices)

In Zoetermeer, someone drilled a hole in the living room wall for a data cable, "assuming that this was a cavity wall". On the other side, in the garage, stood the battery. When the fire service arrived, it saw "flames (…) on the top of the home battery, about 30 centimetres high". Those 30 centimetres are the height of the flames on top of the battery on arrival. How big the jet of flame from the drill hole was is not in the report. The damaged module reached about 80 to 90 °C (verified, appendices).

0 of 3

Dutch fires in the NIPV report in which a spontaneous cell defect was established

Source: NIPV, 26 March 2026, appendices; our own count

Three fires are not a count. The report chose them to investigate. But look at how they started. A fire from drilling through is not something a battery manufacturer can do anything about. And a fire with a self-built system is a risk you take yourself: know what you are doing (opinion).

The 20 kWh: what the NIPV wrote, and what the rule is

Maybe you have heard this one: you are not allowed more than 20 kWh in your house. The NIPV report has that limit too, in footnote 3 on page 14:

"In practice, installations may be coupled with several home batteries. However, when the sum of the energy content exceeds 20 kWh, PGS 37-1 applies to the installation."

(verified that it is there; the content is wrong, see below)

What the guideline itself says

PGS 37-1 is the Dutch safety guideline for energy storage with lithium-ion. EOS is the Dutch abbreviation for an energy storage system. Version 1.0 (December 2023) and version 1.1 (April 2026) both say, word for word:

"PGS 37-1 does not apply to systems used by private individuals (such as home batteries and use in pleasure craft, vessels or vehicles)."

"For an EOS with an energy storage capacity greater than 20 kWh, it is recommended to apply the measures from this PGS nevertheless."

(verified, PGS 37-1 version 1.0 and 1.1)

So the number 20 kWh is real. But it sits in a guideline that excludes home batteries, and for a home it is a recommendation. The footnote turned that recommendation into a rule.

For a business it is different. The exclusion only applies to private individuals. A business with more than 20 kWh of storage does fall under PGS 37-1, and placing it outdoors does not change that (verified, PGS 37-1 version 1.1).

What the ministry says

With an amending decree, the Ministry of Infrastructure and Water Management makes the rules for battery storage binding nationwide. Its draft received responses in a public internet consultation. A report on those responses, the Hoofdlijnenverslag (summary report) of the internet consultation, has been public since 23 October 2026. Word for word:

"Private individuals with a home battery or an electric vehicle or vessel do not fall under this amending decree."

"The original explanatory memorandum (NvT) implied that home batteries, except neighbourhood batteries, had to be excluded from the scope regardless of capacity. The article stating how this was worded in the decree has been amended to do justice to this exception."

(verified, IenW, summary report)

NvT is the nota van toelichting, the explanatory memorandum. The memorandum already excluded home batteries, but the article text of the draft did not do so well enough. The ministry had to repair its own text. Regardless of capacity means: a private individual falls outside it above 20 kWh too. The exception does not apply to neighbourhood batteries (derived from «except neighbourhood batteries»).

The field did not agree among itself. In the same report:

"As an example, one environmental agency states that the amending decree should be changed so that all home batteries fall within the scope of the decree. By contrast, another environmental agency states that home batteries should remain excluded regardless of capacity."

(verified, IenW, summary report)

When the new decree takes effect, I have not checked. That date is therefore not here.

Where do home batteries belong then?

The ministry writes:

"Regulating home batteries is more appropriate through the Besluit bouwwerken leefomgeving, because it concerns a building installation."

(verified, IenW, summary report)

In that Besluit bouwwerken leefomgeving (Bbl), the Dutch building regulations, there was nothing specific about home batteries yet in March 2026. The handout of the Kennisdag 2026, Energie opslagsystemen en thuisaccu's (31 March 2026), word for word: "No specific regulations included in the Bbl regarding energy storage systems" and "No prescribed means regarding EOS systems/batteries in buildings." (verified as of 31 March 2026; whether anything was added since has not been checked)

The NIPV got it right before

In January 2025, the NIPV wrote a guidance document for small storage: Veiligheidsprincipes kleinschalige EOS'en (<20 kWh), version 2.0. It says:

"For the safety aspects of EOSs larger than 20 kWh, PGS 37-1:2023, version 1.0 (December 2023) is available."

(verified, NIPV, 6 January 2025)

«Available», not «applicable». In March 2026 the footnote said «applicable». Between those two documents one word shifted, and a recommendation became a rule.

DateDocumentWhat it says
December 2023PGS 37-1, version 1.0private individuals excluded; above 20 kWh «recommended»
6 January 2025NIPV, guidance on small-scale EOSsPGS 37-1 «available» above 20 kWh
17 March 2026Ministry of IenWthe internet consultation opens
26 March 2026NIPV, report, footnote 3PGS 37-1 «applicable» above 20 kWh
31 March 2026Kennisdag 2026 handoutno specific rules for energy storage in the Bbl
28 April 2026Ministry of IenWthe internet consultation closes
April 2026PGS 37-1, version 1.1private individuals still excluded
23 October 2026Ministry of IenW, summary reporthome batteries fall outside, regardless of capacity

(verified, the documents in the source list)

The confusion sits in the whole system, not with one institute. The NIPV wrote it down wrongly once. The ministry had to repair the text of its own draft. And the environmental agencies did not agree among themselves.

And your insurance?

Policy conditions with a limit of 20 or 40 kWh exist. Those conditions come from one provider, and they are not the rule of the market (verified). Asked by the channel in a press question (20 August 2026), two insurers answered in writing on 25 August 2026:

InsurerLimit on capacityReport it separately
a.s.r."for the private customer we apply no limit"the home battery "does not need to be reported separately"
Univé"no separate limit based on capacity""do not need to be reported separately"

(verified, written answer to the channel)

Both answers say «at the moment». A limit in a policy is a condition for your cover, not a ban. It has nothing to do with PGS 37-1. And an insurer that sets no requirement is not giving a judgement on safety. There are policies with a limit, and insurers without one. So check your own conditions.

What you can do yourself: the steps, and their order

The knowledge is above: the meter cupboard does not simply make your battery voltage-free, and there is no legal 20 kWh limit. The skill is in the steps you take, and in the order you take them in.

Brandweer.nl, the website of the Dutch fire service, divides the steps into two moments: the purchase and the installation. The NIPV guidance from 2025 adds steps, mostly about the location.

MomentStepSource
PurchaseAsk your installer whether the battery has extra safety functions.Brandweer.nl
PurchaseAsk your installer for a maintenance contract.Brandweer.nl
InstallationOnly let a certified installer do the installation.Brandweer.nl, NIPV 2025
InstallationCheck for visible damage. Only install the battery if no damage is visible.NIPV 2025
LocationA cool and ventilated place, such as the shed or the garage.Brandweer.nl
LocationIf possible not in the house, but in a separate space reachable from outside. Protect the battery there against temperature, moisture and dust.NIPV 2025
LocationNot in your escape route, so that in a fire the smoke does not block your way out.Brandweer.nl, NIPV 2025
LocationPreferably on the ground floor, in a place emergency services can reach quickly and easily.NIPV 2025
LocationOn or against a non-combustible surface.Brandweer.nl
LocationA working smoke alarm in the room where the battery hangs.Brandweer.nl
LocationIf possible 0.5 metres around it free of combustible materials, and 1.5 metres above it.NIPV 2025
LocationIf possible in a fire-resistant, liquid-tight tray or enclosure that the fire service can fill with water.NIPV 2025
LocationIn a place where the battery is relatively easy to dismantle.NIPV 2025
AfterwardsHave the battery inspected at least once a year by an installer certified for the installation.NIPV 2025

(verified: Brandweer.nl, Een veilige thuisbatterij, read on 13 November 2026; NIPV, guidance, 6 January 2025)

Connecting it correctly is one step

Think back to Zoetermeer. The system was correctly connected, and still a jet of flame came out of the drill hole. Connecting it correctly is one step, not a guarantee. Or as I put it in the video: drill first, then install. Not install first, then drill (opinion).

The location

On the location, the NIPV goes further than Brandweer.nl. According to the guidance, the location decides two things: how fast the emergency services can get to it, and whether the battery can be removed after an incident (verified, NIPV 2025). Word for word:

"If possible, place the home battery where it is relatively easy to dismantle, so that it can be removed during or after a calamity."

In Losser, the battery went outside after the fire was out, into a container on the driveway. Not every house can do everything in the table at once. The guidance itself adds «if possible»: for the separate space, for the distances and for the tray.

Who knows it

At the incidents in the report, the fire service "could only make limited use of an internal or external person with electrical expertise" (verified, NIPV 2026, p. 4). The report therefore proposes:

"Take stock of the availability of an external expert with electrical knowledge of the installation, such as the installer."

(verified, NIPV 2026, chapter 6)

Among the information the fire service collects, the report lists "Instructions for making it voltage-free" and "Contact details of the installer". And once the incident is stable and electrical (dismantling) work is still needed, that goes to "a competent electrician or installer".

That course of action is a proposal from the report, not yet an established procedure of the fire service. What the source does say: the installer is the expert with electrical knowledge of this specific installation, and he does the dismantling work after the incident. The report does not say that the installer does the voltage measurement. So know who connected your battery, and how to reach them.

When it gets hot, smokes or burns

I do not write down steps for that. Brandweer.nl gives no steps for that moment on the page Een veilige thuisbatterij, and the NIPV report is about what the fire service does, not about what the occupant does. The only switch-off order with a source is the one from the distributor of the AEG SolarCube, and it applies to one product (see below). A step-by-step plan without a source is not something I put here.

And the plug-in battery?

The NIPV report contains no plug-in battery at all. Two other reports show that a plug-in battery is not free of risk either. And both stayed without a fire so far.

AEG SolarCube AS-BBL09: according to the distributor

The first source is the distributor of AEG home batteries in the Benelux: the safety notice on its web shop (undated) and its official statement (PDF, created on 30 October 2026). Trade media reported it on 4 and 5 November 2026. Everything in this section is what the distributor says. I have not checked it myself.

  • Which model. Only the regular AEG SolarCube, type AS-BBL09. Word for word: "This notice only applies to the AEG Solarcube. If you have an AEG Solarcube Pro, you do not need to do anything."
  • What is wrong. The connector between the BMS, the unit on top of the battery pack, and the battery can overheat. The plastic housing can then partly melt, with light smoke and the smell of melted plastic.
  • The cause. A slight dip in the base plate of the BMS. The connector then does not seat fully, the contact resistance rises, and the connector heats up locally.
  • Fire. Word for word: "In theory this is possible, but a melted plug has not led to a fire anywhere yet."
  • How big. After more than 1,100 repairs, a connector still melted on 0.48% of the BMS units (5 units). So the repair stops and all BMS units are replaced: 4,500 units. The new BMS has a temperature sensor in the connector.
  • What an owner has to do. According to the distributor, you switch the battery off and disconnect it from the grid, even if everything works normally, until the BMS has been replaced. In which order you switch off is in the distributor's safety notice (source 11).

0.48%

of the repaired BMS units on which a connector still melted: 5 units after more than 1,100 repairs. After that, all 4,500 BMS units are replaced

Source: the distributor of AEG home batteries in the Benelux, official statement, 30 October 2026; not checked by us

Arithmetically it adds up: 0.48% of 1,100 is about 5 (derived).

Growatt AURA 5000: according to Growatt

The second report is about the Growatt AURA 5000. In an e-mail to the channel of 10 November 2026, Growatt writes:

"unfortunately we have had to decide to temporarily suspend the sale of the AURA 5000. This follows a number of reports of overheating, in which the AC connector partly melted."

(verified, e-mail from Growatt, 10 November 2026)

TechPulse described Growatt's message to owners on the same day. I have not seen that message itself; the quotes below come from TechPulse.

"Users of the Growatt AURA 5000 plug-in home battery are asked to stop using their battery for the time being."

Owners have to switch the battery off and disconnect it from the grid. On what is wrong:

"According to the manufacturer, there have been a few cases in which the AC connection overheated"

In some cases the connection partly melted. How many cases there were is not stated: «a few», no number. And on fire:

"According to Growatt, the overheating has not led to a fire so far."

It is not a recall. The sale is temporarily suspended, and owners must not use the battery for the time being. Status on 10 November 2026: the cause is not yet known, and Growatt is investigating it.

Two sides

Twice it is a connection that gets too hot and melts, and according to the reports without a fire. That puts these two against Zoetermeer and Kollumerpomp. There a drill and a self-built system. Here a connector of the device itself that melts, and you cannot solve that with knowledge or skill (opinion; for Growatt it depends on the cause, and that is not yet known).

The fire service's advice for the plug-in battery

Brandweer.nl published its own advice for the plug-in battery on 7 April 2026 (verified):

  • The location. On the ground floor, in a dry and ventilated room, and never in or near an escape route.
  • The connection. On a separate circuit, not through a power strip or an extension cord, and no two batteries on one socket.
  • The smoke alarm. A smoke alarm belongs with it.

So with the plug-in battery you see two sides. What goes wrong with the device itself is handled by the manufacturer or the distributor, as with AEG and Growatt. Where it stands and how it is connected, you choose yourself. That is what the fire service's advice is about.

My verdict: safe or not?

A home battery can catch fire. So can your tumble dryer, and according to the German estimate about as often, with the battery slightly higher.

I think home batteries, given the number of reported cases and especially how they started, are safer than your phone or your power bank. An opinion, not a count. A fire probability per phone or per power bank per year was not found: searched on 13 November 2026 in Dutch, German, Australian and American sources. What circulates is on blogs without a primary source. And the direction can flip: per device a phone may have a smaller fire probability than a home battery, and per stored kilowatt-hour a larger one.

So who decides whether your battery is safe where it is?

A 20 kWh limit that decides it for you does not exist. Between the guidance of 2025 and the footnote of 2026, one word shifted: «available» became «applicable», and advice became a rule. Hear about a limit somewhere? Look at which word comes with it.

The fire service only comes when there is already a fire. If a fixed home battery burns, the meter cupboard does not guarantee that it is voltage-free. The fire service cools and measures, and waits until it is stable. If the surroundings allow it, it can let the battery burn out in a controlled way.

What remains is you. Where it stands, who connects it and in what order you take the steps, you decide yourself. What is in the device itself, such as the connectors at AEG and Growatt, is outside your control. So take the steps that belong with it, and take them in the right order. A risk always remains.

Safe or not is not only a matter of knowledge, but also of skill.

What is deliberately not in here

The NIPV report contains more than this article. I leave out these topics, because the source behind them was not read or because the claim was not checked:

  • How fast and how intense a fire with a home battery is compared to an ordinary house fire.
  • Whether a home battery increases the chance of a house fire.
  • Hydrogen fluoride (HF) and the research by the RIVM on it.
  • The power per socket and the usual storage capacity of a plug-in battery.
  • «From 3 kWh» as a limit. It is the guide value of one safety region, not a national rule.
  • The date on which the ministry's new decree takes effect.
  • The five incidents abroad from the report.
  • What the regulator does or requires in the AEG recall.
  • A step-by-step plan for when your battery gets hot, smokes or burns. No source for the occupant was found.

Frequently asked questions

Frequently asked questions

Are you allowed more than 20 kWh of home batteries in your house?+

There is no legal 20 kWh limit for a home battery in a house. According to version 1.0 (December 2023) and version 1.1 (April 2026), the guideline with that number, PGS 37-1, does not apply to private individuals. Above 20 kWh it only recommends applying its measures. The Ministry of Infrastructure and Water Management writes that private individuals with a home battery do not fall under the new amending decree, regardless of capacity. For a business, the PGS 37-1 limit is real.

Is my home battery voltage-free when the main switch in the meter cupboard is off?+

Not guaranteed. According to the NIPV, switching off at the meter cupboard offers no guarantee that the home battery is voltage-free. The stored energy stays in the battery and can still deliver voltage. Without voltage measurements it cannot be guaranteed that all parts are voltage-free (NIPV, 26 March 2026, p. 3-4 and p. 20).

How often does a home battery catch fire?+

There is no official count. RWTH Aachen estimated the fire probability of a home battery at 0.0049% per year, about 1 in 20,000 batteries. A tumble dryer is at 0.0037% in the same study. It concerns Germany in 2023, counted from media reports, and only fires the battery itself caused. The study itself was not opened; the numbers come from pv magazine Deutschland and ESS News (9 December 2024).

Do I have to report my home battery to my insurer?+

That depends on your policy. Policy conditions with a limit of 20 or 40 kWh exist, at one provider. a.s.r. and Univé wrote to the channel on 25 August 2026 that at the moment they apply no capacity limit for private customers and that the home battery does not need to be reported separately. Check your own conditions. A limit in a policy is a condition for your cover, not a ban, and has nothing to do with PGS 37-1.

What does the fire service do when a home battery burns?+

According to the NIPV, the Dutch fire service focuses mainly on cooling, monitoring and preventing further escalation into the surroundings. The experts in the report see a controlled burn-out, possibly with cooling from a distance, as a responsible option if the surroundings allow it. A battery only counts as stable again when the thermal imaging camera measures below 50 °C for 15 minutes and an explosion hazard meter no longer measures flammable gases.

Sources

Sources

  1. [1]NIPV, Incidentbestrijding lithium-ion thuisbatterijen (26 March 2026, 51 pages, in Dutch)Read in full on 13 November 2026. Source of: what kind of report it is, the meter cupboard (p. 3-4 and p. 26), the voltage measurement and stranded energy (p. 20), the response and the burn-out (p. 3-4 and p. 4), stable (p. 23), the smoke (p. 20, an expert judgement), the installer and the course of action (p. 4 and chapter 6, a proposal), footnote 3 on p. 14 (the content is wrong) and the three Dutch incidents (appendices).
  2. [2]NIPV, Veiligheidsprincipes kleinschalige EOS'en (<20 kWh), version 2.0 (6 January 2025, in Dutch)Source of: PGS 37-1 «available» above 20 kWh, the location, the distances, the tray, dismantling, the damage check and the annual inspection.
  3. [3]PGS 37-1:2023, version 1.1 (April 2026), online text (in Dutch)Source of: does not apply to private individuals, the recommendation above 20 kWh, and the scope for businesses.
  4. [4]PGS 37-1, publication page (version 1.0, December 2023, in Dutch)Version 1.0 excludes private individuals in the same words as version 1.1.
  5. [5]Ministry of Infrastructure and Water Management, Hoofdlijnenverslag van de internetconsultatie, Wijzigingsbesluit energieopslagsystemen (in Dutch)Public since 23 October 2026. Source of: private individuals do not fall under it, the repair of the article text, the two environmental agencies and the Besluit bouwwerken leefomgeving.
  6. [6]Kennisdag 2026 handout, Energie opslagsystemen en thuisaccu's (31 March 2026, in Dutch)Source of: no specific rules for energy storage in the Bbl, as of 31 March 2026. Whether anything was added since has not been checked.
  7. [7]pv magazine Deutschland, Brandwahrscheinlichkeit von Photovoltaik-Heimspeichern bei 0,0049 Prozent (9 December 2024, in German)On the RWTH Aachen study. Source of the fire probabilities per year, the 50 times and the counting method. The study itself was not opened: the publisher refused the download.
  8. [8]ESS News, Fire risk for home energy storage systems is 0.0049%, says German study (9 December 2024)Second place of publication for the same numbers.
  9. [9]a.s.r. and Univé, written answer to a press question from the channel (25 August 2026)Press question of 20 August 2026. Both answers say «at the moment». Not public.
  10. [10]Brandweer.nl, Een veilige thuisbatterij (in Dutch)Undated, read on 13 November 2026. Source of the steps at purchase and installation.
  11. [11]The distributor of AEG home batteries in the Benelux, safety notice AEG SolarCube (in Dutch)Undated. Source of the model, what is wrong, the cause and what an owner has to do, with the order of switching off. Not checked by us.
  12. [12]The distributor of AEG home batteries in the Benelux, official statement AEG SolarCube (PDF, in Dutch)Created on 30 October 2026. Source of the repairs, the 0.48%, the replacement of 4,500 BMS units and the quote on fire. Not checked by us.
  13. [13]Growatt, e-mail to the channel (10 November 2026)Quoted word for word in the name of Growatt. Not public.
  14. [14]TechPulse, news report on the Growatt AURA 5000 (10 November 2026, in Dutch)On Growatt's message to owners. That message itself was not seen.
  15. [15]Brandweer.nl, news report on the plug-in home battery (7 April 2026, in Dutch)Source of the advice for the plug-in battery.
Video thumbnail: Plug-in batteries lead the Dutch market. And nobody is counting them.

Newest on Jay's Desk

Plug-in batteries lead the Dutch market. And nobody is counting them.

The videos behind these articles. Same numbers, same sources, on video.

Related articles