Tags
2 articles
The datasheet of a home battery often gives an efficiency of about 96%. At night it does not reach that. When discharging, the Conow Atlas 6000 AC reaches 94.8% at 500 W and 78.8% at 100 W. The difference is the fixed loss: what the inverter costs to be on. With the loss in watts instead of the efficiency in percent, the curve becomes simple, and the peak sits in the middle, not at full load. With the measurements per step, the count on the CEC list, a worked example and the sources.
The Conow Atlas 6000 AC costs € 1,523.39, and Conow promises that at least 81% of what goes in comes back out. We put it on our techbench for eight days. At 1500 W, 87 of every 100 kWh came back, socket to socket. At 3000 W it depended on how warm the battery was when charging began: with a warm battery it derates halfway, the charge takes 102 instead of 92 minutes, and less comes back. This is the full file behind the video: every figure with its origin and condition, five charts, control over RS-485, what Conow acknowledged and committed to, and what I do not know yet.
86.7 % efficiency (3000 W)own measurement